Description
The Sanwa DLC460F is a digital leakage clamp meter designed for CAT. III environments.
The DLC460F is a digital clamp meter designed for measuring current leakages in power lines.
The device can measure both currents and voltages along with resistances. It can measure AC current of up to 400 Amperes with an accuracy of 1.2%, and AC/DC voltages of up to 600 Volts with an accuracy of 1.2% as well.
The DLC460F has max/min hold function for holding the maximum or the minimum readings on the screen, as well as a hold function for holding or pausing a reading on the screen. The instrument also features an ACA LPF (Low Pass Filter) function that attenuates high frequencies to reduce noise for accurate readings.
The device requires 2x LR03 batteries for operation and consumes an average power of 33mW. It is compliant with the IEC61010-1 CAT.III 600V, IEC61010-2-032, IEC61010-031 safety standards.
The meter comes with a set of test leads, carrying case and instruction manual.
- ACA LPF (Low Pass Filter)
- 6000 Count Display with Backlight
- MAX/MIN Value Hold, Data Hold
- Auto Power Save
Specifications
Function | Range | Accuracy | Resolution |
---|---|---|---|
ACmA | 60.00mA/600.0mA | ±(1.2%+5) | 0.01mA |
ACA | 60.00A/400.0A | ±(1.2%+5) | 0.01A |
ACV | 600.0V | ±(1.2%+5) | 0.1V |
DCV | 600.0V | ±(1.0%+2) | 0.1V |
Resistance | 999.9Ω | ±(1.0%+8) | 0.1Ω |
Continuity | Buzzer sounds at 30Ω or below Open voltage:Approx. 0.9V |
Sampling rate | 2 times/sec. |
Bandwidth | 40-400Hz |
Display | 6000 (A/V)/9999 (Ω) |
Clamp diameter/Conductor size | Φ35mm/10x40mm |
Battery | LR03×2 |
Battery life | Approx. 90 hrs. Alkaline battery/Backlight off) |
Size/Mass | H206×W83×D38mm / Approx. 320g |
Safety standards | IEC61010 CAT.Ⅲ 600V |